ใบรับรองมาตรฐานและรางวัล
ISO 9001:2015 ระบบบริหารคุณภาพ
![](http://www.asdair.com/images/awardcat/as_d_industry_co.,_ltd._9k_exp.09.10.2026_unlocked-สำเนาต้นฉบับ_1.png)
ISO 9001:2015 ระบบบริหารคุณภาพ
UL Evaluation (USA) (UL Listing R21094)
![](http://www.asdair.com/images/awardcat/1.jpg)
EMME.R21094 Dampers for Fire Barrier and Smoke Applications
-
FDC curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Static Testing).
-
FDC curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Static Testing).
-
FHC curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Static Testing).
-
FDC3 curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Static Testing).
-
FDN louver type fire damper is UL listed with UL 555 Standard with fire rating of 1.5 hours. (Dynamic Testing).
-
FDN3 louver type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Dynamic Testing).
-
HFDN3 louver type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Dynamic Testing).
-
FDCD3 curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Dynamic Testing).
-
FDCDH3 curtain type fire damper is UL listed with UL 555 Standard with fire rating of 3 hours. (Dynamic Testing).
-
SDI louver type smoke damper is UL listed with UL 555S Standard of smoke damper. (Leakage Class I).
-
HSDI louver type smoke damper is UL listed with UL 555S Standard of smoke damper. (Leakage Class I).
-
SDK louver type smoke damper is UL listed with UL 555S Standard of smoke damper. (Leakage Class III).
-
FSDI louver type smoke & fire damper is UL listed with UL 555 Standard with fire rating of 1.5 hours and UL 555S Standard of smoke damper. (Leakage Class I).
-
FSDI3 louver type smoke & fire damper is UL listed with UL 555 Standard with fire rating of 3 hours and UL 555S Standard of smoke damper. (Leakage Class I).
-
HFSDl3 louver type smoke & fire damper is UL listed with UL 555 Standard with fire rating of 3 hours and UL 555S Standard of smoke damper. (Leakage Class I).
-
FSDK louver type smoke & fire damper is UL listed with UL 555 Standard with fire rating of 3 hours and UL 555S Standard of smoke damper. (Leakage Class III).
High Technology Clean Room HVAC Systems
-
FHF fire damper is complied with GB 15930-2007 standard.
-
PFHF smoke& fire damper is complied with GB 15930-2007 standard.
-
PYF smoke exhaust valve is complied with GB 15930-2007 standard.
ใบรับรองสินค้าที่ผลิตในประเทศไทย Made in Thailand (MiT)
![](http://www.asdair.com/images/awardcat/afp_1.jpg)
ท่อลมยืดหยุ่นอลูมิเนียมฟอยล์หุ้มฉนวนใยแก้ว รุ่น AFP
![](http://www.asdair.com/images/awardcat/db_3.jpg)
หัวจ่ายทรงเหลี่ยมติดเพดานคอตรง รุ่น DB
![](http://www.asdair.com/images/awardcat/fd.jpg)
บานควบคุมเพลิง (Fire Damper) รุ่น FD
![](http://www.asdair.com/images/awardcat/fdc.jpg)
แดมเปอร์กันไฟลามรุ่นประตูม้วน รุ่น FDC-T
![](http://www.asdair.com/images/awardcat/gv.jpg)
หัวจ่ายลมใบ 2 ชั้น รุ่น GV-A
![](http://www.asdair.com/images/awardcat/hd.jpg)
บานปรับลม รุ่น HD-T
![](http://www.asdair.com/images/awardcat/ra.jpg)
หัวจ่ายลม Linear รุ่น RA-A
![](http://www.asdair.com/images/awardcat/rc.jpg)
หัวจ่ายลมรีเทิร์นและซัพพลาย รุ่น RC-A
![](http://www.asdair.com/images/awardcat/sla.jpg)
หัวจ่าย Linear Slot รุ่นปรับได้ SLA2-A
BS standard test (UK)
-
AF flexible duct is complied with British BS-476-1989 Standard by passing fire testing
-
AFE insulation fire flexible duct is complied with British BS-476-1989 Standard by passing fire test.
-
FD louver type fire damper is complied with BS-476 Standard of 3 hours of fire rating test.
SIRIM QAS Fire Protection Standard Test (Malaysia)
![](http://www.asdair.com/images/awardcat/04_(a_)afp.png)
AFP Aluminium flexible duct with 25mm fibre glass insulation passes fire propagation tests (Test Report Ref. No: STS 3049/7/1-6)
![](http://www.asdair.com/images/awardcat/04_(b_)fsd.png)
FSD uninsulated multiblade fire damper with fusible link passes fire protection test (Test Report Ref. SQAS/FET/15/1-3)
Fire type approval test (Taiwan)
-
FDCDH3 curtain type fire damper passes 3 hours fire dynamic testing. Certification Number: SD-A9901
-
SD louver type smoke damper passes leakage testing. Certification Number: No.SD-A9901
สำนักวิจัยและบริการวิทยาศาสตร์และเทคโนโลยี (สวท.) มหาวิทยาลัยเทคโนโลยีพระจอมเกล้าธนบุรี
![](http://www.asdair.com/images/awardcat/06_(a)_fd-1.png)
FD louver type fire damper passes heat resistance of fire damper (3 hours).
![](http://www.asdair.com/images/awardcat/06_(b)_fdc.png)
FDC curtain type fire damper passes heat resistance of fire damper (3 hours).
![](http://www.asdair.com/images/awardcat/06_(d)_afp_1.png)
Fusible link passes melting point of fusible link and heat resistance of fire damper (3 hours).
![](http://www.asdair.com/images/awardcat/06_(d)_afp.png)
AFP Aluminium flexible air duct and insulated aluminium flexible air duct passes pressure test at 30 inch H2O (762mm H2O,7.47KPa)
CNAS Testing (China)
![](http://www.asdair.com/images/awardcat/07_cnas_test.png)
AFP2 Insulated Flexible Duct passes entrustment test conducted by National Research Center of Testing Techniques for Building Materials (No. WT2018B03A01271)
VIPAC Airflow Test (Australia)
![](http://www.asdair.com/images/awardcat/08_a_square_diffuser.png)
4-way Square Ceiling Diffusers airflow test conducted by Vipac Engineers & Scientists Co., Ltd. (Report No. 30-B-06-0108_TRP_211369_0)
AS standard test (Australia)
![](http://www.asdair.com/images/awardcat/09(1).png)
AF flexible duct is complied with UL-181-12-1994 by passing AS-4254-1995 high and low temperature test.
![](http://www.asdair.com/images/awardcat/09(2).png)
AF flexible duct is complied with UL-181-17-1994 by passing AS-4254-1995 pull pressure testing
อนุสิทธิบัตร
![](http://www.asdair.com/images/awardcat/10(1).png)
Ceiling Diffuser Set for Air Ventilation System / ชุดโครงหัวจ่ายลมแนวยาวสำหรับระบบปรับอากาศขนาดใหญ่
![](http://www.asdair.com/images/awardcat/10-(3).png)
Double Deflection Supply Grille and Register / ชุดโครงหัวจ่ายลมแบบใบสองชั้น
![](http://www.asdair.com/images/awardcat/10(4-).png)
Low Wind Resisted Louver Type Return Grille / ชุดใบหน้ากากลมกลับแบบแรงต้านต่ำ
![](http://www.asdair.com/images/awardcat/10-(5).png)
Splash Resisted Louver Type Return Grille / ชุดหน้ากากลมกลับรุ่นใบเฉียง
-
Jet Diffuser / หัวจ่ายลมแบบฉีด
ใบรับรองอื่น ๆ
![](http://www.asdair.com/images/awardcat/11(1).png)
AMCA Standard
![](http://www.asdair.com/images/awardcat/11(2).png)
HDR-T-400 Manual Control Damper Pressure Drop & Leakage Test Report